Fluke 707 Loop Calibrator
Mã Số: 
Giá Bán: Contacts us

 

Fluke 707 Loop Calibrator


Provider: Fluke
Category: Fluke-Test tools / Process Calibration Tools
Price: Call us (84-8) 39 572 812
 


The fast, one-handed tool for loop checks. Just click to calibrate. 
This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:
  • Large display and simple, quick-click interface for easy one-handed operation.
  • Simultaneous mA and % readout for quick, easy interpretation of readings.
  • mA accuracy of 0.015%, superior to other loop calibrators in this price range.
  • 1 µA resolution for mA source, simulate and measure.
  • Push button 25% steps for fast, easy linearity checks.
  • 0-100% “span check” for fast confirmation of zero and span.
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
  • Measures V dc to 28 V.
  • Single 9V battery that is easily changed without braking calibration seal
  • 0 - 20 mA or 4 - 20 mA default start up modes.
  • Innovative output adjustment dial with 1 µA and 100 resolution.
  • HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.

Safety conformance

CSA C22.2 No. 1010.1:1992

 

Specifications
Current Measurement
Range: 0 to 24 mA
Resolution: 0.001 mA
Accuracy: 0.015% Rdg + 2 LSD
Current Sourcing
Range: 0 to 20 mA or 4 to 20 mA
Accuracy: 0.015% Rdg + 2 LSD
Drive Capability: 1200 Ω; 950 Ω at 20 mA in HART mode
Current Simulation
Range: 0 to 20 mA or 4 to 20 mA
Accuracy: 0.015% Rdg + 2 LSD
Ext. loop voltage requirement: 12-30 V
Loop Power
  While measuring mA, 24 V
Voltage measurement
Range: 0 to 28 V DC
Resolution: 1 mV
Accuracy: 0.015% Rdg + 2 LSD

Environmental Specifications
Operating Temperature
  -10ºC to 55ºC
Storage Temperature
  -30ºC to 60ºC
Humidity (Without Condensation)
  0 to 90% (0ºC to 35ºC); 0 to 70% (35ºC to 55ºC)
Temperature Coefficient
  -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC

Safety Specifications
Safety
  CSA C22.2 No. 1010.1:1992
EMC
  EN50082-1:1992 and EN55022:1994 Class B
Maximum voltage
  30V (protection circuit for 230V)

Mechanical & General Specifications
Size
  152 x 70 x 41 mm
Weight
  224 g (340 g including holster)
Batteries
  One 9V battery Alkaline
Warranty
  Three years
Shock & Vibration
  per MIL-T-28800 for a Class 2 Instrument
Display current and % of span
  Yes
Auto step, auto ramp
  Yes
Span Check
  Yes