- Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
- GPS time synchronization: Correlate data with events or datasets from other instruments with precision
- Flexible and fully configurable thresholds and scale factors: Allows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances.
- Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages to help determine the cause
- 10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event
- 2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time
- Comprehensive software included: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode
- Plug and play: Allows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries
- Rugged field design: Insulated housing and a solid state design with no rotating components enable reliable testing under nearly any conditions
|
There are four Fluke 1760 models to select from:
Product Feature |
Fluke 1760 Basic |
Fluke 1760TR Basic |
Fluke 1760 |
Fluke 1760TR |
Power quality statistics according to EN50160 |
â— |
â— |
â— |
â— |
Voltage event list (dips, swells and interruptions) |
â— |
â— |
â— |
â— |
Continuous recording of: |
Voltage |
â— |
â— |
â— |
â— |
Current |
â— |
â— |
â— |
â— |
Power P, Q, S |
â— |
â— |
â— |
â— |
Power factor |
â— |
â— |
â— |
â— |
kWh |
â— |
â— |
â— |
â— |
Flicker |
â— |
â— |
â— |
â— |
Unbalance |
â— |
â— |
â— |
â— |
Frequency |
â— |
â— |
â— |
â— |
Voltage and current harmonics to the 50th / Interharmonics |
â— |
â— |
â— |
â— |
THD |
â— |
â— |
â— |
â— |
Mains signaling |
â— |
â— |
â— |
â— |
Triggered recordings |
â— |
â— |
â— |
â— |
Online mode (Oscilloscope, transients and events) |
â— |
â— |
â— |
â— |
Fast transient analysis up to 10 MHz |
|
â— |
|
â— |
4, 600V voltage probes |
|
|
â— |
â— |
4 dual-range flexible current probes (1000 A / 200 A ac) |
|
|
â— |
â— |
GPS time sync receiver |
|
|
â— |
â— |
Memory |
2 GB Flash memory |
Overview of Measurement Functions |
Statistical Evaluation |
|
Power quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI |
|
Event List |
|
Dips, swells and interruptions are detected and stored in the event list. Also any trigger which fires generates an event added to this list. |
|
The Event list shows the exact time when the event occurred as well as the duration and magnitude. Sorting by several attributes of these events is possible to select one for further root cause analysis. |
|
RMS values, transients and fast transients can be stored if a trigger fires. |
|
Continuous Recording |
|
Fluke 1760 records rms values together with corresponding minimum and maximum values for: |
|
• Voltage |
|
• Current |
|
• Power P, Q, S |
|
• Power Factor |
|
• kWh |
|
• Flicker |
|
• Unbalance |
|
• Frequency |
|
• Harmonics/Interharmonics |
|
continuously with the following time aggregations: |
|
Day |
|
10 min |
|
Free Interval, e.g.: 15 min, 2h |
|
Triggered Recordings |
rms: |
Aggregation time is adjustable between 10 ms (1/2 cycle), 20ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles). |
|
Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency. |
|
Basic aggregation for harmonics and interharmonics is 200ms |
Oscilloscope: |
Sample rate is 10.24 kHz for all 8 channels |
Fast Transients: |
Sample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients |
|
Mains Signalling |
|
Phases and N-conductor, Voltage and current |
|
Online Mode |
|
Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events. |
|
General Data |
Intrinsic uncertainty |
|
refers to reference conditions and is guaranteed for two years |
|
Quality system |
|
developed, manufactured as per ISO 9001: 2000 |
|
Environment conditions |
Operating temp. range: |
0 °C to +50 °C; 32 °F to +122 °F |
Working temp. range: |
-20 °C to +50 °C; -4 °F to +122 °F |
Storage temp. range: |
20 °C to +60 °C; -4 °F to 140 °F |
Reference temperature: |
23 °C ± 2 K; 74 °F ± 2 K |
Climatic class: |
B2 (IEC 654-1), -20 °C to +50 °C; -4 °F to +122 °F |
Max. operating altitude: |
2000 m: max. 600 V CAT IV
*
, power supply: 300 V CAT III 5000 m: max 600 V CAT III
*
, power supply: 300 V CAT II
* depending on sensor |
|
Reference conditions |
Environment temp.: |
23 °C ± 2 K ; 74°F ± 2 K |
Power supply: |
230 V ± 10 % |
Power frequency: |
50 Hz / 60 Hz |
Signal: |
declared input voltage Udin |
Averaging: |
10 minute intervals |
|
Housing |
|
insulated, robust plastics housing |
|
EMC |
Emission: |
Class-A as per IEC/EN 61326-1 |
Immunity: |
IEC/EN 61326-1 |
|
Power supply |
Range: |
AC: 83 V to 264 V, 45 to 65 Hz |
|
DC: 100 V to 375 V |
Safety: |
IEC/EN 61010-1 2nd edition |
|
300 V CAT III |
Power consumption: |
max. 54VA |
Battery pack: |
NIMH, 7.2 V, 2.7 Ah |
|
In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as t
| | | |